Installation planning should begin before a commercial speed oven arrives. Buyers should confirm equipment dimensions, counter space, 220 V electrical supply, plug requirements, access route and local installation rules.

This checklist is for cafes, convenience stores, quick-service restaurants, restaurants and equipment buyers. Installation must follow the requirements for the exact model and be completed by qualified professionals where required.

1. Confirm the Exact Model

EOA-1S

EOA-2S

Do not use EOA-1S dimensions to plan for EOA-2S, and do not estimate equipment size from a photograph. Compare both in our model comparison guide.

2. Measure the Counter and Installation Area

Check counter width and depth, available height, door-opening space, employee operating space, cleaning access, service access, adjacent equipment, walls, cabinets and other obstacles.

Required clearances must be confirmed from the installation requirements for the exact model. This article does not provide an unverified universal clearance.

3. Check Counter Stability

The surface should be level, stable and suitable for a commercial kitchen. Confirm it can carry the equipment, remain stable during operation, resist expected heat and cleaning conditions, and allow safe door operation.

Equipment weight has not been provided here. Ask the manufacturer for weight information and have a kitchen designer or installer confirm the counter's load capacity.

4. Plan the Delivery Route

Measure the building entrance, doors, corridors, corners, lift door and interior, stairs, kitchen entrance, passages between counters and final position. Consider packed dimensions, not only bare equipment dimensions.

5. Confirm the 220 V Electrical Supply

EOA-1S and EOA-2S use 220 V only. Before delivery, a qualified electrician should confirm site voltage, circuit capacity, circuit breaker requirements, outlet or connection method, grounding, cable routing, local electrical code and whether a dedicated circuit is required.

This article does not calculate current or specify breaker ratings. Actual requirements depend on the exact equipment, electrical design and local regulations. Do not assume an existing outlet is suitable simply because it is labeled 220 V.

6. Confirm the Plug Requirement

Countries and markets can use different plugs even when they use 220 V. Provide the destination country, operating region, required plug type and buyer or project wiring requirements before production and shipment.

7. Position Electrical Connections Safely

Consider whether the cable could cross a hot surface, become trapped, obstruct staff, contact water or cleaning liquid, and whether technicians can disconnect power safely. A qualified electrician or project installer should determine the final arrangement.

8. Check the Surrounding Environment

9. Catalytic Purification Does Not Replace Local Approval

EOA-1S and EOA-2S support catalytic purification. This does not automatically mean that ventilation, an exhaust system, fire approval or other local requirements do not apply.

Requirements depend on the exact model, menu, cooking volume, location and applicable building, fire, mechanical ventilation and health rules. Obtain confirmation from local authorities or qualified professionals.

10. Confirm the Intended Menu

Tell the supplier what food will be prepared, whether it starts frozen or chilled, whether it contains significant oil, whether it may produce vapor or smoke, expected daily and peak volume, cookware and product dimensions.

11. Confirm Cookware Fits

Check food and cookware dimensions, loading and unloading space, appliance compatibility, door closure and whether cookware affects internal airflow. Do not purchase a large quantity of cookware before compatibility is confirmed.

12. Allow Space for Cleaning and Service

Employees need access to clean the chamber, door, touchscreen, exterior and removable accessories. Technicians also need suitable access for inspection and service.

13. Inspect the Equipment on Delivery

Photograph shipping damage and contact the supplier and carrier. Do not use equipment with obvious door, cable or electrical damage.

14. Complete a Post-Installation Check

Before service, confirm stable placement, compliant electrical connection, normal door operation, touchscreen operation, clear surroundings and air openings, staff understanding of basic operation and cleaning, and availability of test food and cookware.

15. Test the Menu Before Customer Service

For every product, confirm ingredients, portion weight, starting temperature, cookware, settings, internal result, surface finish, food-safety requirements, program name and staff procedure. Frozen and chilled products should be tested separately.

Read our menu programming guide.

16. Train Employees

Training should cover basic operation, correct program selection, standardized portions, approved cookware, safe loading and unloading, unsuitable packaging, daily cleaning, door checks, stopping use when a problem occurs, reporting errors and not opening protective panels.

Microwave, electrical and internal component repairs require qualified personnel.

17. Keep Installation Records

Keep the final order, model and serial number, electrical confirmation, plug requirement, installation date, installer information, test records, menu program records, warranty information, service records and equipment photographs.

EOA-1S or EOA-2S?

For EOA-1S, confirm that the 20 L chamber, 409 × 658 × 630 mm dimensions, 2.2 kW hot-air power and 1.0 kW microwave power match the application.

For EOA-2S, confirm that the 30 L chamber, 580 × 610 × 720 mm dimensions, 3.2 kW hot-air power and 2.0 kW microwave power match the application.

Both require a suitable 220 V electrical supply.

Pre-Delivery Installation Checklist

Frequently Asked Questions

What voltage do EOA-1S and EOA-2S use?

Both use 220 V.

Can I use an existing 220 V outlet?

Voltage alone is not enough. A qualified electrician must confirm circuit capacity, plug, grounding and local requirements.

How much clearance is required?

Confirm this from the installation requirements for the exact model. This article does not provide an unverified universal clearance.

Does catalytic purification remove ventilation requirements?

That conclusion cannot be made automatically. Requirements depend on the model, menu, location and local rules.

Can installation space be estimated from a photo?

No. Use actual dimensions and measure the counter, door operation space and delivery route.

Who should install the equipment?

Installation should be completed by professionals who meet local requirements, especially for electrical work.

Can the oven be used immediately after delivery?

Complete delivery inspection, professional installation, equipment checks, menu testing and employee training first.

Request Model and Installation Information

Provide the required model, quantity, destination country, plug requirement, installation space, intended menu, food and cookware dimensions, and customization requirements.

Email: export04@gzjieguan.com
WhatsApp: +86 138 0275 2018

Request Installation Information